Colourbond-Traditional-Pitched-Roof-under-10-degrees

Metal Traditional Roof <10°

Primary insulation layer NOT parallel to roof plane (Traditional) Metal <10°

All VENT Systems technical advice presents BEYOND COMPLIANCE of the National Construction Code 2025 Vol 1: F8D5 & F8D6 / ABCB Housing Provisions Standard 10.8.3 to ensure mitigation of the risks associated with internal moisture in the roof cavity. BEYOND COMPLIANCE solutions go above and beyond the requirements of the NCC 2025, addressing critical areas such as preventing dew point transference, enabling Class 4 vapour permeable membranes to function effectively, and ensuring unimpeded airflow past insulation. These measures are essential for maintaining optimal conditions within the roof space and minimising the potential for moisture-related issues.

VENT Systems offers a range of solutions compliant with AS3959, AS4200 as well as NCC 2025.

Ventilation of a roof space with the primary insulation layer not parallel to the roof plane: Roof Pitch <10° NCC2025 requires​
FOR COMPLIANCE:
Application for trussed/gable/hipped roofs <10° and >10m²

Opposing ends: 20,000mm²/lm at opposing ends of the roof:

    • Our G2500NOver Fascia Vent 25mm guarantees a calculated airflow of 25,000mm²/lm, ensuring compliance effortlessly at Eaves or Box Gutters.
Application for skillion/mono-pitched <10° and >10m²

Low level: Requires 7,000mm² /lm

    • Our G750N Over Fascia Vent 25mm guarantees a calculated airflow of 25,000mm²/lm, ensuring compliance effortlessly at Eaves or Box Gutters.

High Level: Requires 5,000mm² /lm

  • Our RV10AP-Half Ridge Vent guarantees a calculated airflow >7,000mm²/lm or our BV10 High Level BAL Vent guarantees a calculated airflow of >10,000mm²/LM (5,000mm²/lm p/side), both ensuring compliance effortlessly at the high level.
Application for trussed/gable/hipped roofs <10° and <10m²

Low level: Requires 7,000mm² /lm

    • Our G750N Over Fascia Vent 25mm guarantees a calculated airflow of 7,500mm²/lm, ensuring compliance effortlessly at Eaves or Box Gutters.

High Level: Requires 5,000mm² /lm

    • Pitches 10-15° – Our RV10AP Ridge Vent guarantees a calculated airflow >14,000mm²/lm (>7,000mm² p/side) and/or our BV10 High Level BAL Vent guarantees a calculated airflow of >10,000mm²/LM (5,000mm²/lm p/side), both ensuring compliance effortlessly at the high level.
Application for skillion/mono-pitched <10° and <10m²

Low level: Requires 20,000mm² /lm

    • Our G2500N Over Fascia Vent 25mm guarantees a calculated airflow of 2,500mm²/lm, ensuring compliance effortlessly at Eaves or Box Gutters.

High Level: Requires 5,000mm² /lm

    • Our RV10AP-Half Ridge Vent guarantees a calculated airflow >7,000mm²/lm or our BV10 High Level BAL Vent guarantees a calculated airflow of >10,000mm²/LM (5,000mm²/lm p/side), both ensuring compliance effortlessly at the high level.
Recommended for above compliance:

Our G502 Roll Panel Vent compliance with NCC2025 ensuring a 20mm gap above the primary layer of insulation & ensures unimpeded airflow through the eaves.

The VB10 Ventilation & Drainage Batten 10mm prevents dew point transference by creating a 10mm ventilation & Drainage cavity between the metal roof and the Class 4 vapor permeable membrane.

For bespoke or complex designs there are numerous alternatives that can be considered. Contact our specialist team forfurther assistance.

DISCLAIMER: Product combinations specified within Vent Systems Pty Ltd (ACN 682 448 997) (Vent Systems) technical documentation are designed to mitigate the risk of moisture accumulation and condensation when installed correctly. Unless otherwise indicated, Vent Systems’ individual products or product combinations generally comply with relevant requirements of the Australian Standards and National Construction Code (NCC). However, compliance with NCC minimum requirements alone may not provide adequate moisture and condensation management per sae. Vent Systems can provide professional and tailored advice as to the suitability, specification and installation of ventilation systems. Except to the extent that we have provided tailored advice, to the fullest extent permitted by law, Vent Systems accepts no liability for losses, damages or defects arising from the specification, installation or performance of its products, and does not guarantee any condensation control, moisture mitigation or overall building performance.

Recommended Product Combination for Metal Traditional Pitched Roof <10°

G750N – Over Fascia Vent

The VENT Over Fascia Vent – G750N is the most practical and cost-efficient way to ventilate the eaves on traditional roofs pitched at 15 degrees or more, delivering 7,500mm²/lm of free airflow. Paired with the VB20 Ventilation & Drainage Batten it reaches 22,000mm²/lm, which is enough to meet NCC airflow requirements for pitches under 15 degrees. It is easy to install, sits discreetly hidden behind the spouting, suits both timber and metal fascias, and works with no moving parts or energy use.

VB20 – Ventilated Batten

The VENT Roof Cavity Batten – VB20 is a 20mm polypropylene ventilation and drainage batten that moves 14,500mm²/lm of free airflow through a cathedral roof, between the roofing underlay and the roof battens or purlins. It holds these tight roof cavities open so insulation cannot block them, and works year round with no moving parts or energy use. Fitted behind the fascia and paired with the G750N Over Fascia Vent it reaches 22,000mm²/lm, meeting NCC requirements for pitches under 15 degrees.

G1275 – Eaves Comb Filler

The Eaves Comb Filler G1275 uses flexible fingers that adjust to fill the gaps left by profiled concrete tiles or metal roof cladding, keeping birds and large insects out of the roof while air still flows freely into the cavity. It is a cost-effective replacement for purpose-made fillers that block airflow above the underlay and trap moisture from leaks or dew point. Supplied in 1m lengths, it fits over VENT Systems Over Fascia Vents or directly to timber or metal fascias. For BAL-0 zones only.

G2500N – Over Fascia Vent

The VENT Over Fascia Vent – G2500N is the simplest, most cost-efficient way to ventilate the eaves on cathedral and traditional roofs pitched under 15 degrees. Delivering 25,000mm²/lm of free airflow, it clears hot air from the roof void and manages condensation year round with no moving parts or energy use, while meeting NCC DTS requirements. It is easy to install, sits completely hidden behind the gutter, suits timber and metal fascias, and is the only solution for ventilating a build with no eaves.

G502 – Roll Panel Vent

The VENT Systems Roll Panel Vent G502, also known as an Eaves Baffle or Insulation Guard, holds a 25mm air gap between the insulation and the roofing underlay so air flows freely through the eaves into the roof cavity. Insulation batts can sit full depth above the wall plate with no gaps, cold spots or heel height adjustments, protecting the Energy Star rating that poor eaves insulation erodes. Suitable for concrete and metal roofs, it guarantees compliance with NCC 2022 Vol 1 F8D5 and ABCB Standard 10.8.3.

VB10 – Ventilated Batten

The Ventilation & Drainage Batten 10mm VB10 is a polypropylene batten that creates a 10mm ventilation and drainage cavity between the roofing underlay and the Colorbond cladding, delivering 7,250mm²/lm of free airflow. That separation prevents dew point transferring from the roof sheet to the membrane, and moves hot air into the roof void with no moving parts or energy use. It meets NCC DTS requirements and works well behind lightweight wall claddings or in place of larger over fascia vents.

NCC 2025 Comparison Table

View our NCC 2025 Recommended Products Table for a comprehensive breakdown of roof types, airflow and product specification.

Passive Ventilation Calculator

Need more than the comparison table? We’ve built a super easy-to-use calculator to help you with your ventilation specification and design.

Full Estimation and Design Service

Did you know we offer a full estimation and design service? Visit our estimation page and let one of our ventilation experts help you with your design.

For more info on these products, get in touch with us

Product Data Sheets

Technical Details PDF

Profiled Metal Roofing Ventilated Fascia Detail - Traditional framed roof No Eave - under 15°

Profiled Metal Roofing - Universal Fascia 20mm + G1200N Vent no Eave

Profiled Metal Roofing Ventilated Fascia Detail - Traditional framed roof With Eave - under 15°

Profiled Metal Roofing Boxed Gutter Detail - Traditional Framed Roof

Profiled Metal Roofing - Universal Fascia 20mm + G1200N Vent with Eave

Technical Details DWG

Profiled Metal Roofing Ventilated Fascia Detail - Traditional framed roof No Eave - under 15°

Profiled Metal Roofing - Universal Fascia 20mm + G1200N Vent no Eave

Profiled Metal Roofing Ventilated Fascia Detail - Traditional framed roof With Eave - under 15°

Profiled Metal Roofing Boxed Gutter Detail - Traditional Framed Roof

Profiled Metal Roofing - Universal Fascia 20mm + G1200N Vent with Eave

Product Bundle

Metal Traditional Pitched 10º or less