Concrete_Tile_Traditional_Pitched_Roof_above_15_degrees

Concrete Tile Traditional Pitched Roof ≥15°

Achieving BEYOND COMPLIANCE of the National Construction Code 2022 Vol 1: F8D5 / ABCB Housing Provisions Standard 10.8.3 ensures comprehensive mitigation of the risks associated with internal moisture in the roof cavity. BEYOND COMPLIANCE solutions go above and beyond the requirements of the NCC 2022, addressing critical areas such as the eaves to ensure unimpeded airflow past insulation. These measures are essential for maintaining optimal conditions within the roof space and minimizing the potential for moisture-related issues.

For a Traditional Pitched Roof ≥15°-75° requirement mandates “7,000mm²/lm at the eaves and 5,000mm² at high-level.

Achieving this standard is straightforward and easy.

Our G1200N Over Fascia Vent 10mm guarantees a calculated airflow of 11,000mm²/lm, ensuring compliance effortlessly.

The G502 Roll Panel Vent ensures unimpeded airflow through the eaves.

For High-level ventilation, the G630 Lap Vent is a quick and easy install that allows high-level ventilation in line with NCC requirements, that requires no change of application to wet fix ridge capping.

Recommended Product Combination for Concrete Tile Traditional Pitched Roof ≥15°

G1200N

Over Fascia Vent 10mm

The VENT Over Fascia Vent – G1200N is the most practical and cost-efficient method of ventilating the Eaves of traditional roof pitches ≥ 15°-75°. It is easy to install, discrete and compatible with either timber or metal fascias.

  • 11,000mm²/lm of free airflow
  • Meets NCC DTS requirements
  • Releases hot air from roof voids and manages condensation
  • The only solution to ventilate builds with no eaves
  • It can be used in isolation or as part of a passive ventilation system
  • It can be used to form part of a passive ventilation system that works year-round with no moving parts or energy consumption.
  • Easy to install
  • Not visible as hidden by spouting/gutter

G502

Roll Panel Vent G502

The VENT Systems Roll Panel Vent G502, also referred to as an Eaves Baffle or Insulation Guard, is designed to establish a 25mm air gap between the insulation and the underside of the roofing underlay, ensuring seamless airflow through the eaves into the roof cavity.

Utilising the G502 allows for the seamless installation of insulation batts into the eaves, above the wall plate, without any gaps or uneven layers. Studies have shown a significant reduction in energy loss attributed to improper insulation placement in the eaves, thereby contributing to the attainment of Energy Star ratings.

This product guarantees compliance with the National Construction Code 2022 Vol 1: F8D5 / ABCB Housing Provisions Standard 10.8.3.

Features:

  • Ensures unimpeded airflow through the eaves
  • Ensures compliance with NCC 2022 10.8.3 – FD85
    • 20mm gap above insulations
  • Compatible with Concrete and Colourbond roofs
  • Prevents need for heal height adjustments
  • Prevents cold spots
  • Negates the need for reduced insulation at the eaves
  • Energy star rating efficiencies

G630 Lap Vent

The VENT Systems Lap Vent – G630 is designed to release warm air from the roof void using the natural convection of rising warm air.

The G630 can be used in isolation or as part of a propriety ventilation system. It is highly recommended that the G630 is used in conjunction with low-level eaves or over fascia vents.

The G630 is applied to the highest layer of horizontally laid membrane or sarking within 900mm of the high point of the roof to comply with NCC requirements.

  • 3,000mm²/unit
  • Allows warm moist air to escape the roof cavity
  • Perfect for new builds or retrofit
  • Is highly recommended to only apply high-level vents with some form of Over Fascia or Eaves ventilation
  • Requires no change in ridge capping applications
  • No tools or fixing accessories required
  • Must be applied to horizontally laid membranes
  • Works year-round with no moving parts or energy consumption

G1275

Eaves Comb Filler

The Eaves Comb Filler G1275 is designed with flexible fingers which adjust to fill the gaps left when using profiled concrete tiles or Colourbond roof cladding. This prevents entry by birds and large insects beneath the concrete tiles or Colourbond roofing profile.

The G1275 eliminates the need for expensive purpose-made profiled fillers that can block necessary airflow above roofing underlays that can trap moisture created by leaks or dew points (Colourbond roofs), in the cavity between the underlay and roof covering.

The G1275 can easily be applied in conjunction with other VENT Systems products and can be fitted on top of VENT Systems Over Fascia Vents or directly to metal or timber fascias. It is an excellent product for residential, commercial or school buildings. The G1275 is used outside of the enclosed roof structure and should be used in accordance with the relevant BAL restrictions.

Features:

  • Cost-effective
  • Allows free-flow of air into the roof cavity
  • Compatible with Concrete Tiles and Colourbond roofs
  • Facilitates drainage in case of leaks
  • Profiles to the underside of the roof covering
  • 1m lengths for ease of installation
  • For BAL-0 Zones only

For more info on these products, get in touch with us